Hot Runner Controller (TC-880) |
 |
 |
|
 |
|
 |
| |
|
|
 |
Thermocouple Calibration Accuracy |
: |
0.1 ∩ |
|
 |
Control Accuracy |
: |
【0.3 ∩ from Set point |
|
 |
Control Algorithm |
: |
PID, Auto Tuning |
|
 |
Manual Mode |
: |
Power compensation for incoming voltage variation (0 ~ 65%) |
|
 |
Operation Range |
: |
30 ~ 400 ∩ (86 ~ 752 'F) |
|
 |
Power Output Range |
: |
15Amp/Zone (3600W/Zone) |
|
 |
Standby Temperature |
: |
User selectable (30~400 ∩) |
|
 |
Boost Mode |
: |
1 ~ 99min. 0 ~ 100 % output |
|
 |
Sensor |
: |
Thermocouple Type J, K |
|
 |
Cold Junction Compensation |
: |
Internal to enclosure |
|
 |
External Resistance |
: |
10Meg.Ohms |
|
 |
Temperature Variation |
: |
Due to T/C Length None |
|
 |
Input Voltage |
: |
90 ~ 250VAC, 50/60 Hz |
|
 |
Operation Conditions |
: |
0 ~ 50 ∩ / Up to 90% humidity (Non-condensing) |
|
|
Over voltage protection function |
|
|
|
 |
|
 |
|
|
|
|
|
|
 |
 |
Hot Runner Controller(TC-3200) |
 |
 |
|
 |
|
 |
| |
|
|
 |
Input Power |
: |
3-Phase 3Lines + E(4 wire) 200/240VAC
3-Phase 4Lines + E(5 wire) 380/415VAC
(Other voltages require an input supply transformer) |
|
 |
Frequency Range |
: |
50/60Hz, 【5% |
|
 |
Measurement Accuracy |
: |
【0.5∩ for the range 0∩ to 500∩ |
|
 |
Temperature Stability |
: |
0.3∩ from ambient |
|
 |
Control Stability |
: |
【1 digit-under steady state conditions |
|
 |
Thermocouple Inputs |
: |
Grounded or Ungrounded |
|
 |
Thermocouple Type |
: |
IC(J) or CA(K) Type Supported |
|
 |
Operating Ambient |
: |
0~40∩ (32~104⒌) |
|
 |
Heater Outputs |
: |
All Zones rated at 240VAC.
15 Amps per zone standard. |
|
|
Over voltage protection function |
|
|
|
 |
|
 |
|
|
|
|
|
|
 |
 |
Sequence Injection Timer (TS-800) |
 |
 |
|
 |
|
 |
| |
|
|
 |
Main Power Supply |
: |
Single Phase AC 220V (50/60Hz) |
|
 |
InJection Signal Input |
: |
IN DC24V / AC 110V / AC 220V
(Free Voltage) |
|
 |
Solenoid Valve Voltage |
: |
DC 20V / AC 110V / AC 220V |
|
 |
Solenoid Valve LOAD |
: |
DC 30V / 5A , AC250V / 10A |
|
 |
Operation Conditions |
: |
-10∩ ~ +50∩ |
|
 |
Time RANGE |
: |
9.99 / 99.9 / 999 Sec |
|
 |
Mode Specification |
: |
A Mode/ B Mode/ C Mode |
|
|
|
 |
|
 |
|
|
|
|
|
|
 |
 |
Multi Timer Controller(TS-910) |
 |
 |
|
 |
|
 |
| |
|
|
 |
Main Power Supply |
: |
Single Phase AC 220V (50/60Hz) |
|
 |
InJection Signal Input |
: |
IN DC24V / AC 110V / AC 220V
(Free Voltage) |
|
 |
Power Supply |
: |
2 Port Signal Input Support |
|
 |
Solenoid Valve Voltage |
: |
DC 24V / AC 110V / AC 220V |
|
 |
Solenoid Valve LOAD |
: |
DC 24V / 2A(Total) , AC220V / 3A |
|
 |
Operation Conditions |
: |
-10∩ ~ +50∩ |
|
 |
Time RANGE |
: |
9.99 / 99.9 / 999 Sec |
|
 |
Mode Specification |
: |
A Mode / B Mode / C Mode |
|
|
|
 |
|
 |
|
|
|
|